ROC 400 Series | |
Singleturn, 4096 (12 bits) to 360 position values/rev., Shaft dia.: 10 mm or 6 mm, Parallel TTL or HTL signals. |
Singleturn | ROC 412 | ROC 410 | ROC 409/360 | ||||
Abs.
position values/rev. (absolute measuring step) |
212
= 4096 (approx. 5.28' ) |
210
= 1024 (approx. 21' ) |
360 (1°) |
||||
Accuracy | ± 1/2 bit | ||||||
Data code | Gray code | ||||||
Data interface | Parallel with TTL or HTL levels | ||||||
|
6000
rpm 10000 rpm |
||||||
Protection (EN 60529) | IP 65 | ||||||
Power supply | TTL:
5V HTL: 10 to 30 V |
||||||
Operating temperature | TTL:
Up to 85 °C HTL: Up to 70 °C |
||||||
* for the absolute position value |