Mechanical
Data |
ST
1208
ST 1278
ST 1288 |
ST
3008
ST 3078
ST 3088 |
ST
1207
ST 1277
ST 1287 |
ST
3007
ST 3077
ST 3087 |
Plunger
actuation
Plunger position at rest |
By
measuring object
Extended |
Pneumatic
Retracted |
Measuring
standard |
DIADUR
phase grating on glass; grating period 20 µm |
System
accuracy |
±
1 µm |
Measuring
step |
1
µm/0.5 µm |
Reference
mark |
Approx.
5 mm below upper stop |
Measuring
range |
12
mm |
30
mm |
12
mm |
30
mm |
Gauging force
Vertically downward
Vertically upward
Horizontal
|
0.6 to 1.8 N
0.4 to 1.6 N
0.5 to 1.7 N |
0.7 to 1.4 N
0.3 to 1.0 N
0.5 to 1.2 N |
0.4 to 3.4 N
dep. on pressure and
operating attitude |
0.4 to 2.4 N
dep. on pressure and
operating attitude |
Permissable
radial force |
≤
0,8 N |
Operating
attitude |
Any |
Vibration
(55 to 2000 Hz)
Shock (11ms) |
≤
100 m/s² (IEC 60 068-2-6)
≤ 1000 m/s² (IEC 60 068-2-27) |
Protection |
IP
64 |
Operating
temperature |
10
to 40 °C; reference temperature 20 °C |
Mounting |
Clamping
shank Ø 8h6 |
Weight
(without cable) |
40
g |
50
g |
40
g |
50
g |