Measuring Methods |
Incremental |
Measuring standard |
Glass scale with DIADUR
graduation |
Thermal expansion coefficient
|
αtherm ≈ 8 x 10-6
K-1
|
Accuracy grade |
|
Measuring lengths (ML) in mm
|
|
Incremental signals |
1 VSS |
Grating period |
20 µm
|
Signal period |
20 µm
|
Reference marks |
Distance-coded |
Version
|
Distance-coded; absolute
position value available after
max. 20 mm traverse |
Cutoff frequency -3dB |
≥ 150 kHz
|
Power supply |
5V ±5%/< 120 mA |
Electrical connection |
Sep. adapter cable (1 m/3 m/6
m/9 m) connectable to mounting
block |
Max. cable length |
150 m
|
Max. traversing speed |
120 m/min
|
Required moving force |
≤ 4 N
|
Vibration (55 to 2000 Hz) |
≤ 200 m/s² (EN 60068-2-6) |
Shock (11 ms) |
≤ 400 m/s² (EN 60068-2-27)
|
Operating temperature |
0 to 50 °C
|
Protection (IEC 60529) |
IP 53 when installed according
to the mounting instructions
IP 64 if compressed air is
connected |
Weight
|
0.4 kg + 2.3 kg/m measuring
length |