Skip to product information
HEIDENHAIN EQN 437 Absolute Multiturn Rotary Encoder
Key specifications
- Very high axial tolerance of up to ±1 mm or ±1.5 mm
- Blind hollow shaft, hollow through shaft, or tapered shaft
- Very high positioning accuracy of down to ±20"
- 33 554 432 positions/rev.
- Multiturn functionality for up to 4096 revolutions
- Max. operating temperature: 100 °C
- Absolute rotary encoder with integral bearing and mounted stator coupling
- Multiturn (4096 revolutions)
- Interface: EnDat 2.2/22
- 25 bits positions/rev
- Available with functional safety; Fanuc version EQN 437F
Download historical specifications (2009 catalog, PDF)
Current specifications
May 2026 catalog. Match the full HEIDENHAIN ID, interface and shaft version before selecting a replacement.
- EQN 437, valid for ID 1178025-xx: absolute multiturn, EnDat 2.2 / EnDat22, 33,554,432 positions per revolution and 4096 revolutions; accuracy ±20 arcseconds.
- DC 3.6 V to 14 V; maximum power consumption 0.7 W at 3.6 V and 0.8 W at 14 V; typical current at 5 V 95 mA. M12 flange socket, radial, or 1 m cable with M12 coupling.
- Blind hollow shaft or hollow through shaft, Ø8 or Ø12 mm; mounted stator coupling. Functional-safety versions require their exact product information and ID check; do not substitute the EQN 437F Fanuc version.
Download current EQN 437 specifications (May 2026, PDF)
Historical configuration specifications
From the HEIDENHAIN Rotary Encoders catalog, October 2009. Values are catalog values; confirm your unit's configuration from its ID label.
- EQN 437: absolute multiturn, EnDat 2.2, 33 554 432 positions x 4 096 revolutions, 3.6 to 14 V, up to 140 mA.
- Blind hollow shaft or hollow through shaft D = 8 or 12 mm, mounted stator coupling, IP 67 at housing and IP 64 at shaft inlet, approx. 0.3 kg, –40 °C to 100 °C.
Documents
- HEIDENHAIN ECN 413 / 425, EQN 425 / 437 spec sheet, 2009 catalog (PDF)
- HEIDENHAIN ECN / EQN / ERN 400 universal stator coupling spec sheet, 2009 catalog (PDF)
- HEIDENHAIN Rotary Encoders catalog, October 2009 (PDF)