The HEIDENHAIN LIC 4100 V series is an exposed absolute linear encoder for high-vacuum applications. LIC 4113V uses EnDat 2.2; LIC 4193V variants support Fanuc, Mitsubishi, Panasonic or Yaskawa interfaces. The encoder combines a scanning head with an LIC 4003 glass or glass-ceramic scale secured with fixing clamps.

Technical Data

  • Models: LIC 4113V and LIC 4193V
  • Scale: LIC 4003 with METALLUR grating on glass or Robax glass ceramic
  • Accuracy grades: ±1 µm for Robax glass ceramic only; ±3 µm or ±5 µm
  • Baseline error: no more than ±0.275 µm per 10 mm
  • Measuring lengths: selected lengths from 240 mm to 3040 mm; Robax glass ceramic up to 1640 mm
  • Measuring steps: 10 nm, 5 nm or 1 nm; the 1 nm option is limited to measuring lengths up to 2040 mm for Mitsubishi and 1840 mm for Yaskawa
  • Interfaces: EnDat22, Fanuc05, Mit03-4 or Mit03-2, Pana02, YEC07, depending on the head
  • Traversing speed: up to 600 m/min, subject to interface conditions
  • Interpolation error: ±20 nm
  • Electrical connection: 1 m or 3 m cable with a 15-pin D-sub connector, female
  • Maximum cable length: 100 m for EnDat; 50 m for Fanuc, Panasonic or Yaskawa; 30 m for Mitsubishi, with the specified cable
  • Supply voltage: 3.6 V to 14 V DC
  • Typical current at 5 V: 75 mA for EnDat; 95 mA for the other interfaces, without load
  • Operating temperature: -10 °C to 50 °C
  • Baking temperature: 100 °C
  • Vacuum class: high vacuum down to 10-7 mbar
  • Protection: IP40
  • Scanning-head mass: 18 g without cable

Vacuum installation and selection

The vacuum variants use vented cavities, vacuum-friendly materials and specialized cleaning and packaging to reduce outgassing. The cable has PTFE insulation and tin-plated copper braiding. For the lowest possible outgassing, the product information recommends baking at 100 °C for 48 hours under high-vacuum conditions.

Confirm the exact scanning-head interface, scale material, measuring length, mounting clamps, cable route and vacuum process before selecting a configuration. Standard LIC 4100 parts are not automatically interchangeable with the vacuum variants. The 100 °C baking limit is not the continuous operating-temperature limit.